What are the specifications of guidewires?

Medical guidewires are available in a variety of specifications to accommodate different clinical applications and anatomies. Common specifications include, but are not limited to, the following:

 

  • Diameter

 The diameter of a guidewire is usually measured in inch or mm, with common diameters such as 0.014 inches, 0.018 inches, 0.025 inches, 0.035 inches, 0.038 inches, and so on.

  • Length

 Guidewire lengths are also available in a variety of options, usually ranging from 50cm to 450cm. Depending on the interventional procedure, such as coronary intervention, peripheral vascular intervention or neurovascular intervention, different lengths of guidewire may be required.

  • Tip Shape

 The tip of the guidewire can be straight, J-shaped, or other specialized shapes. the J-shaped tip is often used to reduce the risk of vascular injury.

  • Tip Stiffness

The tip may be soft, moderately stiff, or stiff, depending on the type and condition of the vessel to be crossed.

  • Coating

The wire may contain coatings that help minimize friction, such as silver, silicon, PTFE, hydride coatings, etc. 6.

  • Core Material

Commonly used core materials are stainless steel and nickel-titanium alloy (Nitinol), which is favored for its good flexibility and shape memory properties.

  • Torque Response

The torsional response of a guidewire describes the response of the distal end of the guidewire as it rotates proximally. Some high-end guidewires have very precise torsional control.

  • Shape Memory

Some guidewires can be manipulated according to a preset shape, especially those containing shape memory alloys.

  • Visibility

Guidewires are usually radiolabeled at the distal end for X-ray visualization.

  • Support

The support of a guidewire refers to its stability and strength during advancement, which is critical for advancement and placement of other instruments.

  • Flexibility and Trackability

Flexibility of a guidewire refers to its ability to travel through complex vascular pathways, while trackability describes its compliance in the vasculature and ability to track the catheter.

guidewire components

Each interventional procedure may require a specific size guidewire to provide optimal performance. Therefore, the physician will select the appropriate guidewire specifications based on factors such as the specific type of procedure, the size and tortuosity of the target vessel, and the anticipated mode of operation. Manufacturers often provide an extensive catalog of guidewires with different specifications and features to meet a wide variety of clinical needs.

Send us your ideas and we’ll get in touch with you within 24H!